TMP220 series 200-220 watts medical & ite power adapters tumbler technologies + trumpower 3350 scott blvd., building 13 ? santa clara, california 95054, usa ? 408-988-6616 ? sales@trumpower.com ? www.trumpower.com trumpowe r input specifications input voltage range ............... 90~264 vac input frequency ...................... 47~63hz input current ........................... 3.0a rms @ 115 vac ................................................ 1.5a rms @ 230 vac touch current ......................... 100a max. @ 264 vac, 60hz earth leakage current ........... 300a max. @ 264 vac, 60hz output specifications output power ratings ............ see table tolerance ................................ 5% ripple and noise* .................. 280mv peak to peak max. overvoltage protection ........... set at 110-130% of its nominal output voltage overcurrent protection ........... protected 110-120% of full load ................................................ conditions transient response .............. +4% max. excursion, recovering to 1% of final value within 500s after a 25% load change * measured with 20mhz bandwidth at rated line voltage and output load ranges, with a 47f electrolytic capacitor in parallel with a 0.1f ceramic capacitor across the output. general specifications power factor .......................... 0.95 typical efficiency ................................ 87% min. at 100 vac or 240 vac hold-up time .......................... 12ms min. at 100 vac turn-on delay time ................ 3 sec. max. at 100 vac line regulation ...................... 0.5% max. at full load operating temperature ......... 0 c to +40 c storage temperature ............. -20 c to +80 c relative humidity ................... 10% to 90% non-condensing withstand voltage .................. 4000 vac from input to output, ................................................ 1500 vac from input to ground mtbf ....................................... 125k hours minimum at full load, 25 c ambient, calculated per mil-hdbk-217f features ? class i (c14 inlet) & calss ii (c8 inlet) ? 0.95 active power factor ? 87% minimum efficiency ? medical & ite dual approvals ? short-circuit, ovp, olp, and otp protections ? standby power consumption < 0.5w ? cec & energy star level v compliance ? 100% burn-in at full rated load standards & compliances iec/en 61000-1-2 ................. emc & immunity performance en 55011, en 55022 ............ class b, conducted & radiated fcc, vcci ............................. class b, conducted & radiated en 61000-3-2 ........................ harmonic distortion, class a & d en 61000-3-3 ........................ line flicker en 61000-4-2 ........................ esd, 8 kv air and 6 kv contact en 61000-4-3 ........................ radiated immunity, 3v/m en 61000-4-4 ........................ fast transient/burst, 2 kv en 61000-4-5 ........................ surge, 1 kv diff., 2 kv com. en 61000-4-6 ........................ conducted immunity, 3 vrms en 61000-4-8 ........................ magnetic field immunity, 3a/m en 61000-4-11 ...................... volt age dips, 30% reduction for 500ms, 60% reduction for 100ms, >95% reduction for 10ms safety standards ................... iec/en/ul 60601-1 3rd ed. ............................................... ansi/aami es 60601-1:2005, ............................................... csa c22.2 no. 60601-1:08, ............................................... iec/en 60950-1 2nd ed. agency approvals .................. ul, cul, tuv, ce, cb other compliances .............. rohs, cec & energy star level v models list note: 1) class i models are equipped with iec320/c14 ac inlet. 2) class ii models are equipped with iec320/c8 ac inlet. . o n t c u d o r p s s a l c t u p t u o e g a t l o v m u m i x a m d a o l m u m i x a m r e w o p t u p t u o 9 1 - 0 2 2 p m t i v 9 1a 3 5 . 0 1w 0 0 2 4 2 - 0 2 2 p m t i v 4 2a 7 1 . 9w 0 2 2 8 2 - 0 2 2 p m t i v 8 2a 6 8 . 7w 0 2 2 2 c - 9 1 - 0 2 2 p m t i i v 9 1a 3 5 . 0 1w 0 0 2 2 c - 4 2 - 0 2 2 p m t i i v 4 2a 7 1 . 9w 0 2 2 2 c - 8 2 - 0 2 2 p m t i i v 8 2a 6 8 . 7w 0 2 2
tumbler technologies + trumpower 3350 scott blvd., building 13 ? santa clara, california 95054, usa ? 408-988-6616 ? sales@trumpower.com ? www.trumpower.com TMP220 series 200-220 watts medical & ite power adapters #TMP220_2013-03-23 mechanical specifications unit: inch [mm] tolerance: 0.02 [0.5] maximum weight: 1.0 kg (2.2 lbs.) approx. for TMP220-19 and TMP220-19-c2 only 2 c - 9 1 - 0 2 2 p m t & 9 1 - 0 2 2 p m t r o t c e n n o c t u p t u o c d n i p n o i t c n u f 1 v + 2 v + 3 n r u t e r c d 4 n r u t e r c d l l e h s c n * / d n g c a s l e d o m i i s s a l c n o c n s i l l e h s * notes: 1. standard output connector: mo lex mini-fit receptacle, p/n 39-01-2060 with female terminal #5556 or equivalent. mating connector: molex plug 39-01-2066 and male terminal #5558, #5566, #5569 or equivalent. 2. output connector for TMP220-19 and TMP220-19-c2: kycon p/n kppx-4p 4-pin circular din or equivalent. mating connector: kycon p/n kpjx-4s-s or equivalent. 3. contact trumpower for output connector options. d r a d n a t s r o t c e n n o c t u p t u o c d n i p n o i t c n u f 1 v + 2 n r u t e r c d 3 n r u t e r c d 4 v + 5 v + 6 n r u t e r c d
|